الوصف
Samwha-Dsp EM-07E-XXD-DIN Voltage Current Frequency Apparent Power Protect Multimeter 3P&4W
General
EM-07E-DIN and EM-07E-XXD-DIN Multimeter measures the load on the system and voltage, current, apparent power minimum and maximum values, demands related to this load on the system.
Features
RS485 Modbus RTU (1200 - 38400bps)
53 x 31 Custom Design Glass LCD
3-phase voltage and 3-phase current
transformer
It shows that V1, V2, V3, V12, V23, V31, I1, I2,
I3, S1, S2, S3, F1, F2, F3
It shows the minimum, maximum and
average values of V1, V2, V3, V12, V23, V31,
F1, F2, F3
It shows the minimum, maximum, average
and demand values of I1, I2, I3, S1, S2, S3
High/Low voltage, current, frequency
(adjustable)
Phase-Neutral or Phase-Phase protection
(adjustable)
Can delete the demands
Menu is password-protected
Construction
1 - It shows phase number belong to measurement values
2 - Showing values are minimum of measurement values
3 - Showing values are maximum of measurement values
4 - Showing values are average of measurement values
5 - Showing values are demand of measurement values
6 - It shows Serial Communications
7 - It shows that type of measurement values
Definition of Buttons
ESC Button:
-State of Measurement; Back to home screen.
-State of Menu; Exit menu. State of changing
parameter; Not save chance and back to menu
state.
-State of Error; Manual reset
SET Button:
-State of Measurement: Entry Menu.
-State of Menu: Entry state of changing
parammeter.
-State of changing parameter: save change and
back to menu state
UP Button:
-State of Measurement: To navigate from a main
measurement values to another.
-State of Menu: To navigate from menu
parameters to another.
-State of changing parameter: Increase value of
parameter
RIGHT Button:
-State of Measurement: To navigate from a deep
measurement values to another(min,max,avg,
dmd)
-State of Menu: To navigate from menu
parameters to another
-State of changing parameter: Decrease value of
parameter
Warnings
Use the device according to the instructions specified by us.
Do not expose the LCD display directly to sunlight in order to avoid any harm on it.
Note that the temperature level on the panel to which the device is mounted is at the range ofoperating temperature of the device (-20C.....55C).
There must be a space of 5cm behind the device after its installation.
Fix the device securely to the front-cover of the panel with the apparatus delivered together with the device.
Be sure that the panel to which the device is mounted does not operate in a humid environment.
Place the switch or circuit breaker close to the device or in a location that is easily accessible for theoperator.
Place a switch or circuit breaker on the system during installation of the device.
Please note that the cables must not be energized during installation.
Flexible monitored and twisted cables must be used for the input and output lines which are notconnected to the mains.
The technical personnel according with the instructions specified in the user's manual must performinstallation of the device and electrical connections.
The feeder cables must be compatible with the requirements of lEC 60227 or lEC 60245
Start-up of the Device:
Read the warnings before the device is energized. Make sure that the device is connected according tothe connection diagram. When the device energized for the first time, the Home Screen is displayed. Enterthe current transformer ratio and the voltage transformer ratios*, if installed, on the settings menu at first.
*The EM-07-DIN-XXD and EM-07E-DIN-XXD do not require current transformer ratios
Points to take into consideration in the selection and connection of Current Transformer
Be sure that the current transformer value is higher than the maximum current drawn from the system.
In order to prevent any mistake while connecting the output terminals of the curent transformer, use cables in different colors for each phase or designate a number for each cable.
Keep the cables connected to the output terminals of the current transformer away from the high-voltage line.
In order to prevent any shake on the current transformer, fix it on the bus-bar, cable or rail.
Maintenance
Switch off the device and release from connections. Clean the trunk of device with a swab. Dont use any conductor or chemical might damage the device.
Make sure device works after cleaning.
Specifications
Operating Voltage(Un).......: 85V - 240V AC
Operating Frequency..........: 50/60 Hz.
Operating Power..................:
-
هوية Fruugo:
402945864-855689799
-
EAN:
7801544948215
معلومات سلامة المنتج
يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه
يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.
ملصقات سلامة المنتج
تحذيرات السلامة:
WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
مكونات:
Octinoxate 7.1483%
رقم جزء الشركة المصنعة:
IF273193
رقم الموديل:
IF332227
رقم سري:
IF101416
رقم الدفعة:
IF012594