Adjustable Finger Clip Blood Oxygen Sensor for Adult Pulse Oximeter Monitoring Probes

٩٩٫٠٠ ر.ق.‏
+ ٤٧٫٩٩ ر.ق.‏ الشحن

Adjustable Finger Clip Blood Oxygen Sensor for Adult Pulse Oximeter Monitoring Probes

  • العلامة التجارية: Unbranded

Adjustable Finger Clip Blood Oxygen Sensor for Adult Pulse Oximeter Monitoring Probes

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٢٣٩٫٠٠ ر.ق.‏
السعر: ٩٩٫٠٠ ر.ق.‏
أنت توفر: ١٤٠٫٠٠ ر.ق.‏ (58%)
البائع:
٩٩٫٠٠ ر.ق.‏
+ ٤٧٫٩٩ ر.ق.‏ الشحن

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Item Type: Blood Oxygen Probe Material: Plastic Compatible with CSI models only Specification: LED 660nm/905nm/940nm Maximum Output Power: 15 mW For adult use only, body weight >40kg; designed to be clamped on the index finger or any finger SpO2 Measurement Range: 70%–100% SpO2 Accuracy: ±2% when SpO2 is 90%–100%, ±3% when SpO2 is 70%–89% Pulse Rate Measurement Range: 30–245 bpm Pulse Rate Accuracy: ±3 bpm Main Components: Plug, cable, and probe Intended Use: For use with pulse oximeters and multi-parameter monitors to non-invasively monitor pulse rate and blood oxygen saturation in adult patients (body weight >40kg). Not intended for use under conditions of weak perfusion or motion. Not suitable for long-term continuous monitoring; reposition or inspect the probe site every 4 hours or alternate between fingers. Contraindications: Do not use on tissue-damaged areas. Not suitable for individuals with known sensitivity to PVC, TPU, TPE, or ABS plastics. Warnings: A) Improper placement may result in inaccurate readings. B) Excessive ambient light may interfere with measurement. Shield the sensor with an opaque material if necessary. C) Reposition the probe to a different site at least every 4 hours. Skin condition should be monitored; if skin integrity is compromised, move the probe immediately. D) Presence of intravascular dyes may affect measurement accuracy. E) Motion artifacts may impact performance; not recommended for highly active or restless patients. F) Avoid over-tightening the probe. Excessive pressure may cause venous pulsation and inaccurate readings. G) Route cables carefully to prevent entanglement or patient entrapment. H) Do not use during MRI procedures. Metallic components may cause burns and interfere with imaging. The MRI environment may also affect device performance. I) Do not modify or alter the device. Unauthorized changes may impair function or safety. J) Do not sterilize using radiation, steam, or ethylene oxide without following validated protocols. K) Do not immerse in liquids for cleaning or disinfection. L) Radiofrequency interference from mobile phones or wireless devices may affect sensor operation. Instructions for Use: 1) Insert the fingertip into the sensor until it reaches the stop. Ensure the nail is not excessively long to allow proper contact. 2) Open the lower cover of the finger clamp to ensure even pressure across the padding. 3) Verify correct sensor placement. If the index finger is unsuitable, use another finger. Avoid use on thumbs, toes, hands, or feet in pediatric patients. Note: Choose a monitoring site free from arterial lines, blood pressure cuffs, or IV infusions. 4) Route the cable along the back of the hand to minimize movement. 5) Connect the probe to the compatible oximeter and follow the manufacturer’s operating instructions. Note: If pulse detection is inconsistent, check sensor placement. Thick, thin, or heavily pigmented fingers may impair signal. Reposition or select an alternative sensor type if needed. Maintenance, Cleaning, and Disinfection: A) Inspect for damage and cleanliness before each use. B) Cleaning: Wipe with a soft cloth dampened with mild detergent or soapy water. Dry thoroughly after cleaning. C) Disinfection: Use chemical disinfectants such as ethanol, propanol, or phenol-based solutions. Do not immerse in liquid. Avoid prolonged exposure to UV light. D) Sterilization: If required, use ethylene oxide (EtO) gas at a maximum temperature of 50°C (122°F). Follow aeration guidelines per sterilization equipment instructions. Replacement: Replace every 6 months with regular use. If continued use is necessary, inspect frequently for wear or damage. Storage: After cleaning, disinfecting, and drying, store in a sealed plastic bag. Environmental Conditions: Operating Temperature: 10°C to 40°C (50°F to 104°F) Storage Temperature: -20°C to 60°C (-4°F to 140°F) Operating Humidity: 15% to 90% relative humidity, non-condensing Storage Humidity: 10% to 95% relative humidity, non-condensing
  • هوية Fruugo: 404682635-858772697
  • EAN: 9347182635387

معلومات سلامة المنتج

يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

تحذيرات السلامة: Do not let your children touch this product alone to avoid swallowing or other injuries.

التسليم والرد

يُرسل خلال 24 ساعة

  • STANDARD: ٤٧٫٩٩ ر.ق.‏ - التسليم بين الاثنين 27 أكتوبر 2025 – الثلاثاء 04 نوفمبر 2025

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Qiu Jiateng
  • Wuhan Lili Xing Trading Co., Ltd
  • 9 Jian She 2nd Road, Building 6, Unit, Floor 7, No. 11 Yu Jiang Yi Pin · Qing Shan Yin, Qingshan District, Hubei
  • Wuhan
  • CN
  • 430080
  • jing4808880meif@163.com
  • 15625617190

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • Van Lavazza
  • Y & H S.R.L.
  • Via Gravina 21 MT matera,Trani,Puglia
  • Trani
  • Italy
  • 75100
  • itlyhsrl@gmail.com
  • 0039 3917722149