12V-24V Pulse Signal Cycle Delay Timer Switch dual MOS Control Board

٣٧٫٩٥ ر.ق.‏
والشحن مجاناً

12V-24V Pulse Signal Cycle Delay Timer Switch dual MOS Control Board

  • العلامة التجارية: Unbranded

12V-24V Pulse Signal Cycle Delay Timer Switch dual MOS Control Board

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ٤٨٫٩٥ ر.ق.‏
السعر: ٣٧٫٩٥ ر.ق.‏
أنت توفر: ١١٫٠٠ ر.ق.‏ (22%)
البائع:
٣٧٫٩٥ ر.ق.‏
والشحن مجاناً

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Features:16 opto isolated digital inputs,3 opto isolated digital outputs;Upgrade algorithm,support soft interpolation,fixed arc interpolation bug of the old version;Analog spindle control 0-10V spindle control (can be modified as PWM output);Interface clear and simple, powerful, almost meet all requirementsThere is a key emergency STOP function (STOP key), with reverse connection protection, reverse connection does not burnAdded sleep mode, after enabling, 5 minutes without any operation, automatically close the display, any button to wake upDifferent OP, CL and LOP parameters can be set, which are independent and saved separatelySet parameters for automatic power off and saveWith optocoupler isolation, enhance anti-interference ability, industrial level circuit board, set parameters after power off forever memorySpecification:2: Trigger Source: Active-high (3.0V-24V), have optocoupler isolation, can improve the system's anti-jamming capability (customers can also shorting common ground).Output capacity: 5V--36V DC, 15A continuous current at room temperature, 400W power (maximum current up to 30A under auxiliary cooling conditions)Service life: infinite times switchWorking temperature: - 40~85Weight: Approx.16g/0.6ozOperating mode:P1: trigger signal, the relay is on "OP" time, and then disconnect; in the "OP" time, as follows:P1.1: signal is triggered again, invalidP1.2: signal is triggered again, the clock is resetP1.3: Signal trigger again, relay off, stop the clock;P-2: trigger signal, the relay off "CL" of time, the relay on "OP" time, and then disconnect relay;P3.1: trigger signal, the relay is turned on after the "OP" time, the relay off "CL" time, then the operation cycle, if the trigger signal period, the relay off, stop the clock; the number of cycles ( "LOP ") can be set.P3.2: without triggering signal, the relay is on "OP" time, the relay off "CL" time, and has been cycling; frequency ( "LOP") cycle can be set;P-4: signal holding function. If there is a trigger signal timing is cleared, the relay remains on; when the signal disappears, after the timing "OP" time, the relay is; if another signal during timing, timing is cleared;Pay attention:1. The module is an active output, the output voltage equal to the input voltage.2.'DC + 'and' load + 'This is an internal short circuit of the poles, but' DC- 'and' load - 'poles during use can not be shorted, otherwise the load can not be controlled on and off, which is equivalent load is been carrying electricity.Timing range:How to choose the time range?After setting the mode selection screen parameter value by a short press "STOP" button to select the time range;XXX. decimal point in the unit place, time range: 1 second to 999 seconds.XX. X decimal point in decade place, Timing range: 0.1 seconds to 99.9 secondsX. X. X. decimal full brightness, Timing range: 1 minute to 999 minutes.For example, you want to set "OP" is 3.2 seconds, then move the decimal point to decade place, the digital display 03.2Parameter description: "OP" - conduction time, "CL" - off time, "LOP" - the number of cycles (1-999 times, "---" represents infinite loop).These parameters are independent of each other, but is shared by each mode. For example, in P1.1 mode, set the on-time "OP" is 5 seconds, if you switch to P1.2 mode, it's "OP" will be 5 seconds too.In the main interface (display 000), short press "SET" button will display "OP" ( "CL", "LOP") and the corresponding time XXX;Some parameters only mode "OP" (such as the mode P1.1, P1.2, P1.3), short press the "SET" key to display only the "OP"and the corresponding time;Some models have parameters "OP", "CL", "LOP" (such as the mode P3.1, P3.2), short press "SET" button will display "OP" and the corresponding time, "CL" and the corresponding time, "LOP" and the corresponding number of times;In the main interface by short press "SET" key to see information about the parameters of the current mode, very convenient!How to set parameters?1. First, read the instructions to determine the required operating mode.2. The module is powered up, the display at the current work mode (P1.1 default mode), then enter the main interface; press "SET" button for 2 seconds after release to enter mode selection interface; a short time by pressing "UP", "DOWN" key to select the mode (P1.1 ~ P-4).3. Select the mode (such as P3.2), short press the "SET" button, then the parameter to be set flashes ( "OP" on-time, "CL" off time, "LOP" cycles ( "---" represents infinite loop)), by "UP", "DOWN" keys to adjust the parameter value, support long press (rapid increase or decrease) and short press (increase or decrease one unit); then short press the "STOP" key to select the decimal point position, select the time range (0.1 seconds to 999 minutes); short press the "sET" button to set the next parameters of the current mode of procedure is as above.4. After the parameters are set, long press "SET" button for 2 seconds then release, the name of the current mode w
  • هوية Fruugo: 426750556-895902679
  • EAN: 7708428675758

معلومات سلامة المنتج

يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

ملصقات سلامة المنتج

CE Mark
تحذيرات السلامة: Warning: Please read the product instructions carefully before use to ensure correct use.
رقم سري: 7708428675758

التسليم والرد

يُرسل خلال ٢ أيام

  • STANDARD: مجاناً - التسليم بين الثلاثاء 04 نوفمبر 2025 – الاثنين 10 نوفمبر 2025 - مجاناً

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Shenzhen Mutalai Technology Co., Ltd.
  • Shenzhen Mutalai Technology Co., Ltd.
  • 71001-187, 7/F, Building D, Gaoke Mansion, No. 2076 Yuanyuan Avenue
  • Nanshan Street
  • Nanshan District
  • Shenzhen
  • CN
  • 518000
  • gbyhynnygt@126.com
  • 18664978705
  • https://detail.1688.com/offer/593788918206.html?spm=a2615.7691456.autotrace-offerGeneral.7.4cc915345wLsDx

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795
  • https://www.noon.com/uae-en/p-29378/